Low Cost Operator Interface Stations |
||
T1 with TCU111-S mounted on left |
Toshiba PLCs have a simple ASCII protocol that gives your PC access to all the registers. Several third party user interface packages support it - or ask Transtronics about writing custom a GUI (graphic User Interface) for your application. Do-it your-self-ers will want to download the computer link manual
T1 systems can expand up to
three ways (some units don't have card
slots) You
can use plug-in cards, expansion unit, and a T2 type card expansion
rack.
Everything you need to explore the exciting world of PLC's - includes a TDR116 (8 in/8out + two screwdriver inputs) T1 brick type PLC, programming cable, T1 manual, 3 Programming manuals, plus a PDF & DOC viewers on CD! (printed versions are available for an additional charge) Plus, we throw in free T-PDS Windows95/98/98SE/NT/2K/XP software without support (With unlimited telephone support it sells for $495!) This is a great deal - get in on it while it lasts! (We can substitute any of the T series controllers on request with a similar special.) Price $239
Order number Click for price |
Price | Description |
---|---|---|
T_Starter-kit | $39.00 | Requires the purchase of a PLC or processor unit. Everything you need to explore the exciting world of PLC's - includes a programming cable, plus a PDF & DOC viewers on CD! (printed versions are available for an additional charge) Plus, we throw in free T-PDS Windows95/98/98SE/NT software without support (With unlimited telephone support it sells for $495!) This is a great deal - get in on it while it lasts! (We can substitute any of the T series controllers on request with a similar special.) |
T | DR | 1 | 16 | S | 6 | S |
---|---|---|---|---|---|---|
T = T Series | DR = DC I/O version | 1 = T1 Series | 16 = 16 IO | S = Super | 6 = uses 120/240Vac Power | S = enhanced version |
AR = AC I/O version | 28 = 28 IO 9 | - = older obsolete version 9 |
3 = uses 24Vdc Power | C = economy version 10 | ||
40 = 40 IO |
Part Number click for price |
Description |
---|---|
TDR116S6S | Super T1-16, RTC, RS485, 8 Inputs 24 Vdc, 6 Outputs Relay, 2 Outputs Transistor, 120/240 Vac Powered. |
TDR116S6C | Super economy T1-16, 8 Inputs 24 Vdc, 6 Outputs Relay, 2 Outputs Transistor, 120/240 Vac Powered. |
TDR116S3S | Super T1-16, RTC, RS485, 8 Inputs 24 Vdc, 6 Outputs Relay, 2 Outputs Transistor, 24 Vdc Powered. |
TDR116S3C | Super economy T1-16, 8 Inputs 24 Vdc, 6 Outputs Relay, 2 Outputs Transistor, 24 Vdc Powered. |
TAR116S6S 1 | Super T1 RTC, RS485 8 Inputs 120 Vac, 6 Outputs Relay, 2 Outputs Triac, 120/24 Vac PS |
TDR116-6S 2 | T1 8 Inputs 120 Vac, 6 Outputs Relay, 2 Outputs Triac, 120/240 Vac Powered. |
TAR128-6S 1,2 | T1 14 Inputs 120 Vac, 12 Outputs Relay, 2 Outputs Triac, 120/240 Vac Powered |
TDR128-3S 2 | 14 Inputs 24 Vdc, 12 Outputs Relay, 2 Outputs Transistor, 24 Vdc Powered |
TDR140S6S | Super T1-40, RTC, RS485 24 Inputs 24 Vdc, 14 Outputs Relay, 2 Outputs Transistor, 120/240 Vac Powered |
TDR140S3S | Super T1-40, RTC, RS485 24 Inputs 24 Vdc, 14 Outputs Relay, 2 Outputs Transistor, 24 Vdc Powered |
TAR140S6S 1 | Super T1-40, RTC, RS485 24 Inputs 120 Vac, 14 Outputs Relay, 2 Outputs Triac, 120/240 Vac Powered. |
1 AC IO is avoided for cost and safety reasons - if possible use DC I/O. If you need to sense just a couple of AC inputs look at our Logic level converters.
2 These are older obsolete versions - not inteded for new designs.
Part
Number click for price |
Description |
---|---|
T1-40
Expansion card
holders allows T1-16 PLCS to use T1-40 I/O expansion |
|
TBU101--S | 1 Slot Expansion Card Holder for T1-16S, Holds T1-40 I/O Expansion Card. |
TBU104--S | 4 Slot Expansion Card Holder for T1-16S, Holds T1-40 I/O Expansion Card. |
Descrete or on/off I/O cards | |
TDD116M-S | 8 Inputs 24 Vdc, 8 Outputs Transistor, Mounts on side of T1-16S, order Pigtail connector (EX10-KIO20 3) seperately |
TDI116M-S | 16 Inputs 24 Vdc, Mounts on side of T1-16S, order Pigtail connector (EX10-KIO20 3) seperately. |
TDO116M-S | 16 Outputs Transistor, Mounts on side of T1-16S, order Pigtail connector (EX10-KIO20 3) seperately. |
TRO108M-S | 8 Outputs Relay, Mounts on side of T1-16S. |
Analog Input cards | |
TAD121M-S | 1 Analog Input, 0 - 20 ma/1 - 5 Vdc, 12 bit, Mounts on side of T1-16S. |
TAD131M-S | 1 Analog Input, +/- 10 Vdc, 12 bit, Mounts on side of T1-16S. |
TTC111M-S | 1 Thermocouple Input, Type E, J, K or Millivolt, Mounts on side of T1-16S. |
Analog Output cards | |
TDA121M-S | 1 Analog Output, 0 - 20 ma/1 - 5 Vdc, 12 bit, Mounts on side of T1-16S. |
TDA131M-S | 1 Analog Output, +/-10 Vdc, 12 bit, Mounts on side of T1-16S. |
Networking cards | |
TDN111M-S | DeviceNet Slave Module, Mounts on side of T1-16S. |
TFR112M-S | TOSLINE F10 Remote Station, Mounts on side of T1-16S. |
TCU111-S | Not a card but mounts next to PLC. Multi-drop converter, RS485 to RS232, Communications between host and T1s |
3 Pigtails are often landed to terminal strips - other connectors available you special order are the EX10-ANC32 – solder cup and TPT15-AS crimp-to ribbon cable. call for details and availability
Part Number click for price |
Description |
---|---|
Descrete or on/off I/O cards | |
TDD116-BS | 8 Inputs 24 Vdc, 8 Outputs Transistor, Fits inside T1-40, order Pigtail connector (EX10-KIO20 3) seperately. |
TDI116-BS | 16 Inputs 24 Vdc, Fits inside T1-40 , order Pigtail connector (EX10-KIO20 3) seperately. |
TDO116-BS | 16 Outputs Transistor, Fits inside T1-40, order Pigtail connector (EX10-KIO20 3) seperately. |
Analog input Cards | |
TAD121-BS | 1 Analog Input, 0 - 20 ma/1 - 5 Vdc, 12 bit, Fits inside T1-40. |
TAD131-BS | 1 Analog Input, +/- 10 Vdc, 12 bit, Fits inside T1-40. |
TTC111-BS | 1 Thermocouple Input, Type E, J, K or Millivolt, Fits inside T1-40. |
Analog Output cards | |
TDA121-BS | 1 Analog Output, 0 - 20 ma/1 - 5 Vdc, 12 bit, Fits inside T1-40. |
TDA131-BS | 1 Analog Output, +/- Vdc, 12 bit, Fits inside T1-40. |
Networking Cards | |
TFR112-BS | TOSLINE F10 Remote Station, Fits inside T1-40. |
TCU111-S | Not a card but mounts next to PLC. Multi-drop converter, RS485 to RS232, Communications between host and T1s |
3 Pigtails are often landed to terminal strips - other connectors available you special order are the EX10-ANC32 – solder cup and TPT15-AS crimp-to ribbon cable. call for details and availability.
### ??? TPT15S-AS Connector, Same as EX10-ANC32
The expansion racks take T2 style cards - the expansion units provide extra T1 style I/O
Expansion Racks | |
---|---|
TBU152-S | 2 Slot Expansion with/cable for T1-40, Uses EX100/T2 I/O Modules |
TBU154-S | 4 Slot Expansion with/cable for T1-40, Uses EX100/T2 I/O Modules |
Expansion Units | |
TDR132E-S | 16 Inputs 24 Vdc, 16 Outputs Relay, w/cable, 1 per T1-40. |
TAR132E-S 4 | 16 Inputs 120 Vac, 16 Outputs Relay, w/cable, 1 per T1-40. |
1 AC IO is avoided for cost and safety reasons - if possible use DC I/O. If you need to sense just a couple of AC inputs look at our Logic level converters.
Connectors and Cables | |
---|---|
TPT1T2-AS | Extra T1-28 Removable Terminal Strip, 21 point. |
TPT1T4-AS | Extra T1-40/Super T1-40 Removable Terminal Strip, 31 point. |
EX10-KIO20 | Cable for T1 Discrete I/O Modules or T2 Hi Density (32 Pt) I/O Modules, 2m, One end I/O connector other end pigtail. |
TPT15F-AS | Connector, Flat ribbon cable. |
EX10-ANC32 | Soder-cup Connecter for T1 Discrete I/O Modules or T2/V2000 32 pt Hi Density I/O Modules. |
TCS1R2-CS | Replacement expansion cable for connecting TBU152/154 to T1-40. |
Programming cables | |
TKRS232T1 | Programming Cable, Connects T1 Programming Port to Computer RS232 Port, 2m. |
TCJ105-CS | Programming Cable, Connects T1 Programming Port to HP911/Computer RS232 Port. 5m. |
Programming
Programming | |
---|---|
T-PDS | T Series Computer Programming Software, 3.5" Disks and Software User's Manual. MINIMUM COMPUTER = MS Windows 95 or later. With phone support |
TRM102-S | Program Storage Module (EEPROM), Load/Save/Compare programs without a computer or THP911 handy programmer. Order TCS7688-T2 for use with T2 processors. |
THP911A-S | Handy Programmer THP911, Hand Held, For programming all T- Series Controllers, Includes built-in EEPROM for program storage, Includes cable for T1 controller. Requires adapter TCS7688-T2 for connection to T2 CPUs. |
Manuals | |
---|---|
UM-TS01-E001 | T1 Basic Hardware and functions |
UM-TS01-E031 | T1-16S Basic Hardware and Functions. |
UM-TS03-E025 | THP911 Handy Programmer Operation Manual. |
UM-TS01-E034 | T1-16S I/O Modules. |
UM-TS01-E033 | T1-16S Computer Link Function (Memory Map and Protocol). |
UM-TS03-E045 | T-PDS Windows Software Basic Operation Manual, Ver. 2 |
UM-TS03-CDROM | Package of All
Programmable Controller Manuals, Brochures, Application Notes,
etc., both T Series & EX Series. |
Specifications for Super T1-16S PLCs | |
---|---|
Program | |
Program Control | Stored Program, Cyclic Scan: Scan is selectable; floating or fixed time. |
Language | Ladder diagram with easily inserted function blocks. |
Capacity | 8192 Steps of Program
Memory 4096 Words of Data Registers, 256 Timers, & 256 Counters Discrete I/O 144 Points max |
Program Memory | RAM (capacitor back-up) and EEPROM (no back-up battery required) |
RAM memory back-up | 1 hour at 25C by built-in capacitor, 2 years at 25C by optional battery |
Program capacity | 8K steps (4K or 8K mode) |
Instructions | Basic: 21, Function: 97 |
Execution speed | 1.4s/contact, 2.3s/coil, 4.2s/16-bit transfer, 6.5s/16-bit addition |
Program types | 1 main program 1 sub-program (initial program) 1 timer interrupt (interval: 5 to 1000ms, 5ms units) 4 I/O interrupt (high-speed counter and interrupt input) 256 subroutines (up to 3 levels of nesting) |
I/O capacity | Main unit: 16 points (8 inputs/8 outputs) Expansion I/O: Up to 8 I/O modules (expandable up to 144 points) |
User data I/O register | 512 points/32 words (X/XW, Y/YW) Auxiliary relay 4096 points/256 words (R/RW) Special relay 1024 points/64 words (S/SW) Timer 256 points (T./T), 64 @ 0.01s & 192 @ 0.1s Counter 256 points (C./C) Data register 4096 words (D) Index register 3 words (I, J, K) |
Real-time-clock/calendar | +/-60s/month (not included with ecconomy model |
Special I/O functions | High speed counter (2 single or 1 quadrature) or Interrupt
input (2 points), Adjustable analog register (2 points), (Also known as screwdriver inputs) Pulse output (CW+CCW or pulse+direction) or PWM output |
Communications interface | 1 port of RS232C (programmer port) Programmer or
Computer link protocol TOSLINE-F10 remote (by using TOSLINE-F10 module) The following are on the enhanced version only: 1 port of RS485 Computer link mode (Programmer or Computer) , Data link mode, Free ASCII mode, Inverter (VF-A7/S9) connection mode |
Debug support function | Sampling trace (8 devices and 3 register - 256 times) On-line programming (at 4K mode) On-line EEPROM write |
Network | Computer link, Tosline F10 (On slelected models) |
Enviornmental | |
Ambient temperature | 0 to 55C (operation), -20 to 75C (storage) |
Ambient humidity | 5 to 95% RH, no condensation |
Noise immunity | 1000V p-p/1??s, 89/336/EEC (EMC directive) |
Vibration immunity | 9.8m/s2 (1g), (for 30 minutes per axis, on 3 mutually perpendicular axis) |
Shock immunity | 98m/s2 (10g), (3 shocks per axis, on 3 mutually perpendicular axis) |
Supported Standards | UL/c-UL, CE |
Dimensions (mm) | T1-16 (L122 x W90 x D74.5), T1-28 (L167.5 x W90 x D82), T1-40 (L167.5 x W90 x D85). |
Transistor Output Max current | 0.5A 24Vdc |
T1-16S Electrical | |
Power | |
Power supply | AC powered units - 100 to 240Vac (+10%, -15%) 45 VA or less DC powered units - 24Vdc (+20%, -15%) 18 W or less |
5Vdc power for I/O units Max. | 1.5A (when 24Vdc service power is not used) (this specification can limit the number of I/O cards) |
Service power output Max. | 24Vdc @ 0.2A (power for exciting limit switches and transducers) |
Withstand voltage | 1500Vac for 1 minute (between power terminals and ground terminal) |
Descrete Inputs | |
Input points | 8 points (8 points/common) |
Input voltage - Rated | 24Vdc, +10/-15 % |
Input current - Rated | 7m A (at 24Vdc) |
Minimum ON voltage | 15Vdc |
Maximum OFF voltage | 5Vdc |
ON/OFF delay time | 0 to 15ms (user selectable, default setting is 10ms) |
Relay Output Specifications | |
Output points | 6 points (6 points/common) |
Maximum voltage | 240Vac/24Vdc |
Maximum Current | 2A/point (resistive), 4A/common |
Minimum load | 5Vdc - 10mA |
ON/OFF delay time | 10m s or less |
DC Output specifications | |
Output points | 2 points (2 points/common) |
Maximum voltage | +24Vdc |
Maximum Current | 0.5A/point (resistive) |
Off state Leakage current | 0.1m A or less |
ON/OFF delay time | 0.1m s or less |
Terminal block | Non removable with M3 screw |
3209 W.9th street Lawrence, KS 66049 USA |
Ph | (785) 841 3089 (785) 841 3089 inform@xtronics.com https://xtronics.com |
Bookmark this page |