· 0-30 mV, 0-200 mV, +/- 15mV, +/-100 mV Field Selectable Inputs
· 5, 10 or 24 VDC Field Selectable Excitation Power Supply
· Easy Single Button Scaling with Lockout Feature
· 11 Point Linearization
· Peak Hold Feature
· Capture or Programmable Tare Feature
· Steady, Accurate Display to +/- 199,990
· NEMA 4X Front Panel
· 4 Visual Alarm Points with Front Panel LED Status Indication
· 2 or 4 Relays + 4-20 mA Output Options
Led Status IndicationA green LED labeled "T" illuminates when the PD 691 displays a tared value and a Green LED labeled "P" illuminates when the PD691 displays a peak value.
SpecificationsInputs: Field selectable, 0-30 mV, 0-200 mV, +/- 15mV, +/-
100 mV.
Display: Bright, large, 0.56" (14.2 mm) high efficiency red. 4
˝
digits = extra zero : +/- 19999(0).
Isolated Power Supply: Selectable 5 or 10 VDC +/- 5% @ 50 mA; or
24 VDC
+/-5% @ 20 mA. Available for either strain gauge or 4-20 mA output
option.
Peak Hold Indication: Front panel LED.
Tare: 2 modes. Capture- Sets a currently displayed reading to
zero via
front panel Tare button and may be reset at any time. Programmable-
Automatically subtracts a user selected tare value from the actual
reading.
Tare Indication: Front panel LED
Accuracy: 0.05% of full scale, +/- 1 count.
Lockout: Dip switch restricts modification or calibration values.
Power: 115 VAC or 230 VAC +/- 10%, 50/60 Hz, 10 VA.
Enclosure: 1/8 DIN, high impact plastic, UL 94V-0.
Front Panel: NEMA 4X, panel gasket provided.
Connections: Removable screw terminal block (provided).
Alarm Points: 4,any combination of high or low alarms.
Alarm Status Indication: Front panel LED.
Alarm Dead-band : 0-100% of full scale, user selectable.
Update Rate: 400ms for display (add relay mechanical delay of 50
ms for
total update to output delay.)
Rating: 2 or 4 relays; SPDT (form C). The contacts are rated
2 Amp @
30 VDC or 2 Amp @ 250 VAC resistive load; 1/14 HP @ 125/250 VAC for NC
contacts
and 1/10 HP @ 125/250 VAC for NO contacts, inductive load.
Reset: User select.
Fail-safe Operation : The relay coils are energized in the
non-alarm
condition. In the case of a power failure, the relays will go to the
alarm
state. May be disabled with internal jumper.
Auto Initialization: When power is applied to the meter, the
relays will
always reflect the state of the input to the meter.
Dead-band: 0-100 %, User Selectable.
Calibration Range: Anywhere in range of meter, 501 count
minimum span.
Output Loop Resistance: 1500 ohms max, using a 35V external
power supply.
500 ohms max. Using a built-in power supply. Built-in loop power supply
available for either 4-20 mA output or signal input, but not both.
Accuracy: +/-0.1% FS, +/-.004 mA
Isolation: 500 VDC or peak AC, input -to- output or
input/output-to-power
line.
External Loop Power Supply: 35 V max.
| Model | Description |
|---|---|
| PD691-3-N | with no options |
| PD691-3-14 | 2 relays |
| PD691-3-15 | 4-20mA output |
| PD691-3-16 | 2 relays + 4-20mA output |
| PD691-3-17 | 4 Relays |
| PD691-3-18 | 4 Relays + 4-20mA output |
| Use a -4 instead of a -3 to specify 230 Vac powered meters at no extra cost. | |
![]() |
3209 W.9th street |
phone (785) 841 3089 FAX (785) 841 0434 E-mail inform@xtronics.com WEB http://www.xtronics.com |
Prices subject to change
| Transtronics Home Page See our line of industrial control electronics |
Back to PLC'sIndex | Resource library handbooks, primers and spec sheets. | Process Control Panel Meters |
4sale | E-mail pd@xtronics.com |
bookmark this page
![]() |
3209 W.9th street Lawrence, KS 66049 USA |
phone (785) 841 3089 FAX (785) 841 0434 E-mail inform@xtronics.com WEB http://www.xtronics.com |
Corporate information and privacy
statement
(C) Copyright 1994-2007, Transtronics, Inc. All rights reserved
Transtronics® is a registered trademark of Transtronics, Inc.