Process Control Universal Panel Meter

All standard process signals including Thermocouple and RTD!

Details  Specifications Pricing

Features and Options
Serial Communication PDC or modbus protocols over RS232 or RS485
Meter copy Allows cloning of meter settings over special cable PDA7420
Square root capable Used for flow rates with differential pressure
Display intensity Dim the meter for special applications
Relay output options Automatic reset only
Automatic or manual reset
Latching or non-latching relays
Pump alternation control
On and off time delays from 0 to 199 seconds
Fail-safe operation is user selectable
Min Max Hold min and max readings
Meter View software Windows® 95/98/ME/2000/XP
Communications: RS-232 Adapter or RS-422/485 Adapter
Protocol: PDC
Meter Address: 00 - 99
Baud Rate: 300 - 19,200 bps
Configuration: One meter at a time
Data logging report: Save as HTML file format
Configuration report: PDC file, print, or export HTML

EASY SETUP & PROGRAMMING

The Trident is easy to setup and program and everything is done using the simple four-button programming method. There is only one switch on the entire meter, no jumpers, and no need to ever open the case. The meter can also be programmed using a PC and the MeterView software or “cloned” with the Copy function.

User Friendly Menu Structure

To simplify programming, the Trident’s setup functions are divided into two menus. A main menu handles all the basic setup functions. An advanced features menu handles the special functions not commonly used.

Setting Numeric Values

The numeric values are set using the Right and Up arrow buttons. Press Right arrow to select next digit and Up arrow to increment digit value. The digit being changed is displayed brighter than the rest. Press the Enter/ACK button, at any time, to accept a setting or Menu button to exit without saving changes.

Offset Adjustment

This function allows the user to select an offset adjustment to the temperature being displayed. This value can be either positive or negative and can be any number within +/-19.9°.

Noise Filter and Noise Filter Bypass

The noise filter averages any minor or quick changes in the input signal and displays the reading with greater stability. The noise filter bypass allows larger input changes to be displayed immediately; If the change in input signal exceeds the bypass value, no filtering will occur and the new value will be displayed immediately.
Model selection - Pricing

Specifications
Inputs
TYPES SUPPORTEDField selectable: ±20 mA DC and ±10 VDC enabling 0-20mA,4-20 mA, 1-5V, 0-5V, 0-10V, thermocouples; type J, K, T, or E and platinum RTD (0.00385 or 0.00392 curve)
ACCURACY ±0.05% of calibrated span ±1 count, square root: 10-100% F.S.
LOW-FLOW CUTOFF0 to 9999 (0 disables cutoff function).
INPUT IMPEDANCEVoltage mode: greater than 1 MΩ , Current mode: 50-100 Ω
INPUT OVERLOADProtected by automatically resettable fuse
TEMPERATURE DRIFT±50 PPM/°C
Temperature Inputs
THERMOCOUPLE RESOLUTION1°; type T, 1° or 0.1°
COLD JUNCTION REFERENCEAutomatic
TEMPERATURE DRIFT±2°C maximum; 0 to 65°C ambient temperature
OFFSET ADJUSTMENTProgrammable to ±19.9°. This parameter allows the user to apply an offset value to the temperature being displayed.
General
DISPLAY0.56" (14.2 mm) red LEDs. Four digits (-1999 to 9999)
DISPLAY INTENSITYEight user selectable intensity levels
DECIMAL POINTUp to three decimal places: d.ddd, dd.dd, ddd.d,or dddd
CALIBRATIONInternal or external signal or with PC
CALIBRATION RANGEUser Programmable over entire range of meter
TRANSMITTER SUPPLYIsolated, one or two transmitter supplies (Optional) P1: 24 VDC ±10% @ 200 mA max. (-1 option) P1 & P2: 24 VDC ±10% @ 200 mA & 40 mA max. (-2 option)
FRONT PANELType 4X, NEMA 4X, IP65. Panel gasket provided.
PROGRAMMING METHODSFour front panel push buttons, PC and MeterView software, or cloning with Copy feature.
NOISE FILTERProgrammable between 2 and 199 (0 will disable filter).
DISPLAY UPDATE RATEProcess/RTD: 3.7-5/sec; T/C: 1.8-2.5/sec
OVER-RANGEDisplay flashes 9999
UNDER-RANGEDisplay flashes -1999
RECALIBRATIONAll inputs are calibrated at the factory.
MAX/MIN DISPLAYStored until reset by user or meter is turned off.
NON-VOLATILE MEMORYAll programmed settings are stored in nonvolatile memory for a minimum of ten years if power is lost.
POWER - Standard model85 - 265 VAC, 50/60 Hz, 20 VA  90-265 VDC, 20 W
POWER - low voltage model 12-36 VDC or 12-24 VAC
REQUIRED FUSEUL Recognized, 5A max, slow blow (up to 6 meters may share one fuse)
COMMON MODE REJECTION64 dB at 50/60 Hz
ISOLATION4 kV input/output-to-power line; 500 V input-to-output or output-to-P1/P2 supplies
ENVIRONMENTALOperating temperature range: 0 to +65°C Storage temperature range: -40 to +85°C Relative humidity: 0 to 90% non-condensing
CONNECTIONSPower & Signal: removable screw terminal blocks accept 12 to 26 AWG. Serial: RJ11 header, standard on all meters.
WARRANTY2 years parts and labor
EXTENDED WARRANTYWarranty may be extended an additional 12 months by returning the Product Registration Form within 2 months from date of sale.
Physical 
ENCLOSURE1/8 DIN, high impact plastic, 94V-0, color; gray
WEIGHT 8 oz (2.27 g) (no options)
Relays (option)
RATING2 SPDT (form C); rated 3 amps @ 30 VDC or 3 amps @ 250 VAC resistive load; 1/14 HP @ 125/250 VAC for inductive loads
DEADBAND (Hysteresis)0-100% of full scale, user selectable
HIGH OR LOW ALARMUser may program any alarm for high or low.
AUTOMATIC RESETRelays reset when the input passes the reset point. Manual reset: Front panel ACK button.
TIME DELAY0 to 199 seconds, on and off delays; programmable.
FAIL-SAFE OPERATIONProgrammable, independent for each relay. Relay coils are energized in non-alarm condition. In case of power failure, relays will go to alarm state.
AUTO INITIALIZATIONWhen power is applied to the meter, relays will reflect the state of the input to the meter. Isolated 4-20 mA Transmitter Output
4-20mA output (Option)
OUTPUT RANGE1.00 to 23.00 mA typical
CALIBRATIONFactory calibrated for 4-20 mA
SCALING RANGE0.00 to 23.99 mA, see output range above
ACCURACY±0.1% F.S. ±0.004 mA
TEMPERATURE DRIFT50 PPM/°C from 0 to 65°C ambient Note: Analog output drift is separate from input drift
ISOLATION500 V input-to-output or output-to-P1/P2 supplies; 4 kV output-to-power line
EXTERNAL POWER35 VDC maximum
OUTPUT LOOP RESISTANCEPower supply minimum maximum
24 VDC 10 Ω 700 Ω
35 VDC (external) 100 Ω 1200 Ω

Model selection - Pricing


RELAY OPERATION MODES:

The extra Large bezel is rated Type 4X, IP65.
PD765 mounting

Mounting Notes:

connector

connections

Transtronics, Inc. 3209 W.9th street
Lawrence, KS 66049
USA

Ph
FAX
Email
WEB

(785) 841 3089
(785) 841 0434
inform@xtronics.com
http://xtronics.com





Notes:
1. Panel cutout required: 1.772" x 3.622" (45mm x 92mm)
2 Panel thickness: 0.04"– 0.25" (1.0mm – 6.4mm)
3. Mounting brackets locked in place for easy mounting


Transtronics, Inc. Logo Registered trademark

3209 W.9th street
Lawrence, KS 66049
USA

Ph
FAX
Email
WEB

(785) 841 3089
(785) 841 0434
inform@xtronics.com
http://xtronics.com

Bookmark this page

 

Transtronics Home Page
See our line of industrial control electronics

PLC's Index

EPROM programmer

Process Control
Panel meters

BVUPS

Resource library handbooks, primers and spec sheets

Corporate information and privacy statement
(C) Copyright 1994-2007, Transtronics, Inc. All rights reserved
Transtronics® is a registered trademark of Transtronics, Inc.